A new type of a sound intensity probe employing microelectromechanical systems (MEMS)-based microphones is presented. The intensity probe operates on the p-p principle that uses two pressure signals to calculate one component of the sound intensity vector. The MEMS intensity probe consists of two hybrid-packaged silicon-micromachined piezoresistive microphones mounted in a solid rigid sphere of known diameter. This arrangement enables an analytical correction for probe scattering effects. The MEMS intensity probe is calibrated in a free field and compared with a commercial Brüel & Kjær 3599 intensity probe and a single microphone. Experimental data reveal good agreement between all three probes. These results demonstrate the potential of extending this technique to three dimensions.
AIAA May 2003