Characterization of a Fully-Differential, Dual-Axis, Capacitive Wall Shear Stress Sensor System for Low-Speed Wind Tunnels

This paper describes the development and experimental characterization of a fully-differential, dual-axis wall shear stress sensor system designed to be non-invasive to low-speed aerodynamic flows. The differential capacitive microelectromechanical systems (MEMS) sensor is fabricated using a novel, low-cost approach to creating backside electrical contacts, providing a hydraulically smooth surface without the use of through-silicon vias. Fully-differential, dual-axis sensor electronics provide improved common-mode rejection, reduced environmental sensitivity, and increased shear stress sensitivity, thus increasing the dynamic range of the sensing system. Use of fully-differential charge amplifiers provides improved performance compared to a single-ended voltage amplifier configuration. Initial characterization of the sensor system with differential charge amplifiers yields wall shear stress sensitivities of 4.24 mV/Pa and 6.87 mV/Pa for the two axes, resulting in input-referred minimum detectable signals at 1 kHz of 0.16 mPa and 0.06 mPa, respectively. Dynamic calibration also provides cross-axis rejection ratios of 28.3 dB and 27.4 dB and pressure rejection ratios of 80.7 dB and 77.1 dB.

AIAA Jun 2019

David Mills(1), William Patterson(1), Brett Freidkes(2), Casey Keane(3), Mark Sheplak(1)(2)

Interdisciplinary Consulting Corporation (1), Interdisciplinary Microsystems Group, University of Florida (2), Scandia National Laboratories (3)