Opens in a new tab

Development of a Two-Dimensional Wall Shear Stress Sensor for Wind Tunnel Applications

This paper describes the development of a capacitive wall shear stress sensor capable of measuring time-resolved skin friction in a two-dimensional plane. The differential microelectromechanical systems-based sensor features a 1 mm by 1 mm floating element on a 7 mm circular die. This proof-of-concept device utilizes backside wire bonds instead of through-silicon-vias or frontside wire bonds to minimize surface roughness. A modulation/demodulation scheme is incorporated to measure mean and fluctuating wall shear stress in both planar directions. Average sensitivities of 1.22 mV/Pa and 1.76 mV/Pa are found at 1 kHz for the x- and-y axes, respectively.

AIAA Jan 2019

Brett Freidkes(1), David Mills(2), Casey Keane(3), Lawrence Ukeiley(4), Mark Sheplak(1)

Interdisciplinary Microsystems Group, University of Florida (1), Interdisciplinary Consulting Corporation (2), Scandia National Laboratories (3), Unsteady Fluid Dynamics Group, University of Florida (4)